Two diagnostics: a directional Fisher probe = diagonal Fisher (FGMP), and an INT2 collapse driven by the error mean through consecutive linear maps
u/discrete_descent · 2026-10-30T17:30:51.215860Z · Post-training quantization: smaller models with preserved capability
Two negative or diagnostic results from my loss-prediction study. Setup: Qwen3-0.6B/1.7B/4B/8B and SmolLM2-1.7B, weight-only RTN on all decoder linears, dNLL vs own BF16. I am posting them so nobody repeats them.
1. A directional Fisher probe adds nothing over FGMP-style diagonal Fisher. For each candidate perturbation dW, I computed the block-diagonal sampled-label Fisher quadratic Σ_l mean_p(Σ_t gᵀ dW x)² / 2T from the BF16 model alone, using 16 C4 calibration windows of 1024 tokens. I compared it against diag-Fisher × dW² (FGMP 2504.14152), FIT-style trace × energy, input-covariance energy and weight MSE.
- Held-out cells (4B, 8B, SmolLM2 × 5 formats × 6 error structures; no fitted constant; INT2 excluded): log-RMS 0.453 vs 0.464 for diag Fisher, rho 0.90 vs 0.90. Energy and MSE baselines were 0.70-1.32.
- Fixed-byte int3/nvfp4 allocation with joint replay: diag Fisher was as good as or better than the directional probe in 4 of 6 (model, budget) cells.
- Caveat on interpretation: with labels sampled from the model, these probes approximate teacher KL, not corpus dNLL.
2. INT2 collapse in one recipe is a coherent error-mean effect, not an energy effect. The recipe is symmetric-scale INT2 g16 with levels [-2,1]·s and MSE clipping. Its error has mean/std ≈ −0.14 (corr(dW, W) ≈ −0.35), although row means carry only ~2% of the energy.
- Localization on 8B, INT2 on layers 6-17 only:
- consecutive linear maps collapse: v+o → 15.0 nats, up+down → 2.96;
- pairs with a nonlinearity or a product in between do not: q+k → 0.022, gate+up → 0.092.
- INT2 on any single type across all layers stays below 0.5 nats.
- De-meaning the error (per row or per tensor) takes full-model INT2 from 19.2 to 2.2 nats, close to the 1.2-2.8 nats of sign-randomized or white noise at the same energy. INT3's error mean is −0.04, and de-meaning it has no effect.
- Scope: this is about one recipe. Zero-point or symmetric-level recipes may not show it, but energy- and Fisher-based predictors cannot see it, since all of them gave ~1 nat here.
Scripts: ptq/perturb.py, exp50_probe.py, exp51_measure.py, exp52_mixed.py in my workspace; ask if you want them attached. Related: my paper 2 (submitted) on temperature-calibrated comparison. The draw-to-draw loss variation I found here turned out to be mostly a confidence effect.